In the previous issues, we have studied the principles, characteristics, structure and installation and use methods of plate heat exchangers. In this issue, we will take a closer look. Design selection of plate heat exchangers and application in heat flow field.

Plate heat exchanger selection criteria and key points

1. Selection criteria

Principle 1: Look at the plate type

1. The plate type or corrugated type should be based on the heat exchange Depends on the actual needs of the location.

2. For situations where the flow rate is large and the pressure drop is small, the plate type with small resistance should be selected. On the contrary, the plate type with large resistance should be selected.

3. According to the fluid pressure and temperature, decide whether to choose the assembly type or the brazing type.

4. When determining the plate type, it is not advisable to choose a plate with a single plate area that is too small to avoid too many plate numbers, a small flow rate between plates, and a too low heat transfer coefficient. It is more suitable for larger heat exchangers. Pay attention to this topic.

Principle 2: Look at the process and flow channels

p> The process refers to a set of parallel flow channels in a plate heat exchanger in which a medium flows in the same direction, while the flow channel refers to the medium flow channel formed by two adjacent plates in the plate heat exchanger. Under normal circumstances, several flow channels are connected in parallel or series to form different groups of cold and hot medium channelsRwandans EscortTogether.

The process combination form should be determined based on heat transfer and fluid resistance calculations and meeting process conditions. Try to make the convective heat transfer coefficients in the cold and hot water flow channels equal or close to Rwanda Sugar to obtain the best heat transfer effect. Because the heat transfer coefficient obtains a larger value when the convective heat transfer coefficients on both sides of the heat transfer surface are equal or close to each other. Although the flow rate between the plates of the plate heat exchanger is different, when calculating the heat transfer and fluid resistance, the average flow rate is still used for calculation. Because the “U”-shaped single-flow receiver is fixed on the compression plate, it is easy to disassemble and assemble.

Principle 3: Check the pressure drop check

When designing and selecting a plate heat exchanger, there are generally certain requirements for the pressure drop, so it should be checked. If the calibrated pressure drop exceeds the allowable pressure drop, the design selection calculation needs to be carried out again until the process requirements are met.

2. Key points for selection

1. Flow rate and value:

①. Heat exchange pipe network flow rate: refers to the inlet and outlet pipes, see the flow rate table.

②. Unit main pipe flow velocity: when the pipe diameter Rwanda Sugar ≦ 80, choose 1m/s, when ≧ 100, RW EscortsSee flow chart.

d7d8c238-81fc-11ed-8abf-dac502259ad0.jpg

③. Corner hole flow velocity: maximum 6m/s (four inlets and outlets).

④. Flow velocity between plates: 0.4 ~ 0.8m/s (L type 0.8, M type 0.6, H type 0.4).

2. Heat exchange area:

Refers to the area of ​​the heat exchanger. The area of ​​the single plate * the number of heat exchange plates involved (the total number of plates minus two)

① Calculation of the heat exchange area:

Heat exchange area = heat transfer amount/heat transfer coefficient/logarithmic average temperature difference/fouling coefficient

②. Calculation of heat transfer amount:

Change Rwandans EscortHeat = building area * heating target (i.e. heat load, see target table)

d7f3e946-81fc-11ed-8abf-dac502259ad0.jpg

3. Media parameters:

① , District heating: hot gas heating/geothermal heating: 110/75 ℃ – 50/75

②. District heating: geothermal heating: 110/75 ℃ – 40/50 ℃

③. Building air conditioning: fan coil heating: 110/75 ℃ – 50/60 ℃

Rwanda Sugar ④. Domestic hot water : Rwandans Escort Bath, kitchen, laundry room: 70/50 ℃ – 10/55 ℃

⑤. Swimming pool water supply: swimming Pool constant temperature water supply: 110/70 ℃ – 10/40 ℃

⑥, Rwanda Sugar Daddy Super high-rise air conditioning and refrigeration: cold water conversion : 7/11 ℃ – 8/Rwandans Sugardaddy12 ℃

Methods and formulas for plate heat exchanger selection calculation Nowadays, software selection is generally used for plate heat exchanger selection calculations. The conventional hand calculation methods and formulas are as follows:

(1) Find the heat load Q

Q=G.ρ.CP.Δt

(2) Find the inlet and outlet temperatures of hot and cold fluids

t2 =t1+ Q /G .ρ .CP

(3) Hot and cold fluid flow rate

G=Q / ρ .CP .(t2-t1 )

(4) Find the uniform temperature difference Δtm

p> Δtm=(T1-t2)-(T2-t1)/In(TRW Escorts1-t2)/(T2- t1) or Δtm=(T1-t2)+(T2-t1)/2

(5) Select plate type

If all plate types are selectedWhen completed, the results will be analyzed.

(6) From the K value range, calculate the plate number range Nmin, Nmax

Nmin = Q / Kmax .Δtm .F P .β

Nmax = Q / Kmin .Δtm .F P .β

(7) Get the number of plates N (Nmin≤N≤Nmax)

If N has reached NmaxRwanda Sugar Daddy

a>, do (5).

(8) Take the process combination form of N. If the combination form is finished, do (7).

(9) Find Re, Nu

Re = W .de/ ν

Nu =a1.Rea2.Pra3

(10) Find a, K heat transfer area F

p> a = Nu .λ/ de

K= 1 / 1/ah+1/ ac+γc+γc+δ/λ0

F=Q /K .Δtm .β

( 11) Calculate the required number of plates NN from the heat transfer area F NN

NN= F/ Fp+ 2

(12) If N

(13) Calculate the pressure drop Δp

Eu = a4.Rea5

Δp = Eu .ρ.W2 .ф

Rwandans Sugardaddy(14) If Δp>Δ Yes, do (8);

If Δp ≤ Δ Yes, record the result and do (8).

Note: 1. (1), (2), and (3) are calculated based on known conditions.

2. When T1-t2=T2-t1, use Δtm = (T1-t2)+(T2-t1)/2

3. The modification coefficient β is generally 0.7~0.9.

4. Pressure drop modification coefficient ф, single process ф = 1 ~ 1.2, two process, three process ф = 1.8 ~ 2.0, four process ф = 2.6 ~ 2.8.

5.a1, a2, a3, a4, a5 are constant coefficients.

d804cab8-81fc-11ed-8abf-dac502259ad0.png

d82391c8-81fc-11ed-8abf-dac502259ad0.png

Choosing a plate heat exchanger means choosing the area of ​​the plates. There are two important ways to choose it, but these two All are difficult to understand. The simplest is to apply the formula:

Q=K×F×Δt

Q——heat load

K——heat transfer coefficient

F—— Heat exchange area

Δt——Heat transfer temperature RW Escorts difference (commonly used logarithmic temperature difference)

Heat transfer coefficient Depending on the structure of the heat exchanger itself, each plate with different flow channels has its own empirical formula. If it is not strict, it can be 2000~3000. The finally calculated area of ​​the plate exchange must be multiplied by a certain coefficient, such as. 1.2.

Application of plate heat exchanger in heat circulation field

District heating system

d832d156-81fc-11ed-8abf-dac502259ad0.png

Combined heat and power system

d85fce68-81fc-11ed-8abf-dac502259ad0.png

Geothermal water heating system

d877e138-81fc-11ed-8abf-dac502259ad0.png

Instantaneous domestic hot water system

d8a468c0-81fc-11ed-8abf-dac502259ad0.png

Instant heating feature

Guaranteed useRwanda Sugar Daddy Households can have hot water supply anytime and anywhere. The system is compact and does not require storage tanks. It requires a larger boiler capacity and a larger heat exchanger. .

Semi-instantaneous domestic hot water system

d8bf7b9c- 81fc-11ed-8abf-dac502259ad0.png

Semi-instantaneous heating characteristics

It requires a smaller boiler capacity and a smaller heat exchanger. Bacteria are easy to grow in the storage tank and require additional Storage tanks are installed in the place.

Swimming pool constant temperature maintenance system

d8e95fd4 -81fc-11ed-8abf-dac502259ad0.png

Solar hot water system

e0827b90-81fc-11ed-8abf-dac502259ad0.png

Cooling and air conditioning system

e108d2da-81fc-11ed-8abf-dac502259ad0.png

Condenser side utilization:

1 Cooling tower water cooling condensed water

2 Sea water, river water or well water cooling condensed water

3 Ethylene glycol cooling condensed water

4 Short circuit refrigeration unit RW EscortsSystem

5 Underground cooling/heat source system

6 Heat recovery system

The condensate water side heat exchanger can play the following roles:

Protect the condenser from Contamination, scaling and corrosion

Replace the condenser with cooling water side pressure

Can be used during the seasonDo not run the refrigeration unit when conditions permit

Able to achieve heat recovery

Save expensive additives

Cooling tower water cooling condensed water

e13a841a-81fc-11ed-8abf-dac502259ad0.png

Seawater, river water, or well water cooling condensed water

e16ab2d4-81fc-11ed-8abf-dac502259ad0.png

Ethylene glycol cooling condensed water

e19556ec-81fc-11ed- 8abf-dac502259ad0.png

Short-circuit refrigeration unit system

e1bae51a-81fc-11ed-8abf-dac502259ad0.png

Groundwater cooling/heat source system

e1e4cf7e-81fc-11ed-8abf-dac502259ad0.png

Heat recovery system

e2313c42-81fc-11ed-8abf-dac502259ad0.png

Utilization of evaporation side:

1 Pressure relay system

2 Separate cooling circulating water (no pressure relay function)

3 Ice storage system

4 District cooling system

5 Ceiling cooling system

Evaporation The heat exchanger on the unit side can play the following roles:

Prevent the refrigeration unit from being exposed to high pressure (pressure relay system)

Rwandans Sugardaddy

a>Reduce the use of expensive and inefficient additives

Separate the cooling water system to ensure that the local system is highly clean (electronic components give birth)

Reduce the damage and loss caused by leakage

Pressure Relay system

e257ca2e-81fc-11ed-8abf-dac502259ad0.png

Separate cooling circulating water system

e27ef0fe-81fc-11ed -8abf-dac502259ad0.png

Ice storage system

e2ad591c-81fc-11ed-8abf-dac502259ad0.png

Basic elements of ice storage system design:

Settings Rwanda Sugar Air conditioning requirements

Operation plan

Full ice storage system

Partial ice storage system

Refrigeration unit as the main system

Storage Rwandans EscortIce-based system

District cooling system

e2d25f32-81fc-11ed-8abf-dac502259ad0.png

Ceiling cooling system

e32f602e-81fc-11ed-8abf-dac502259ad0.png

Other application plans for air conditioning systems

1 Summer and summer cooling and heat conversion

p> e365aa62-81fc-11ed-8abf-dac502259ad0.png

2 Chilled water pre-cooling system

e394803a-81fc-11ed-8abf- dac502259ad0.png

Advantages of plate heat exchangers in cooling and air conditioning systems

1. High heat transfer coefficient, logarithmic temperature difference can reach 0.5 degrees.

2. Small size , light weight, easy to install, can be placed on the equipment layer

3. Easy to install, easy to clean external dirt

4. Sturdy structure, can withstand high working pressure, up to 3.0MPa. > 5. High heat exchange efficiency, reduced operating costs

6. Low fixed investment

Basic principles of plate heat exchange units

e3b6d284-81fc-11ed-8abf-dac502259ad0.png

The high-temperature water (secondary return water) flowing through the user’s heat sink passes through After the filter is decontaminated, it is pressurized by the circulation pump and enters the heat exchanger. RW Escorts receives the heat released by the primary heating medium and reaches the water supply setting. After the temperature is reached, it flows to the heating pipe network to provide heat to users;

The source flows through the primary heat network (primary water), passes through the filter, the regulating valve, and enters the heat exchanger to release heat (secondary water). It returns to the heat source (secondary return water) from the heat medium return pipe to be heated and then participates in circulating heat exchange again;

The water replenishment pump performs constant-pressure replenishment of the secondary circulating water system in a timely manner according to the operating conditions of the system.

Review editor: Tang Zihong


Original title: Technology: Design selection of plate heat exchangers and application of heat flow fields

Article Source: [Microelectronic Signal: Communication Power Technology, WeChat Official Account: Communication Power Technology] Welcome to add tracking and follow! Please indicate the source when transcribing and publishing the article.


Experimental research and performance evaluation of plate heat exchangers Experimental research and performance evaluation of plate heat exchangers This paper mainly focuses on the establishment of laboratory heat exchanger test benches, and designs a set of high-automation , a heat exchanger comprehensive performance testing system with accurate measurement, simple operation and wide application range. And based on the data from the plate heat exchanger test, it was published on 04-16 13:53
In addition to the maintenance and repair of the plate heat exchanger, the plate heat exchanger should also undergo regular inspections under special circumstances. Maintenance and repairs. Because plate heat exchangers are easy to disassemble and assemble, maintenance and repairs are simple, and generally no special tools and equipment are required. Different methods can be adopted according to different situations. If the equipment is published on 12-10 14:10 • 14 times downloaded
Plate heat exchanger usage introduction and basic parameters, the contents of this book provide a guide to the use of plate heat exchangers. Published on 05-06 18:43 • 18 downloads
Plate heat exchanger gasket replacement procedures and basic parameters for everyone to learn. The plate heat exchanger sealing gasket is an extremely critical component of the detachable plate heat exchanger. , The application range of plate heat exchangers is also largely restricted by sealing gaskets, and the requirements for sealing gaskets in highly corrosive media are extremely high. 's avatar Published on 11-12 09:41 •6760 views
Classification of plate heat exchangers_functions of each component of plate heat exchangers Plate heat exchangers are made of It is an old-style high-efficiency heat exchanger formed by stacking a series of metal sheets with a certain corrugated shape. 's avatar Published on 11-12 09:50 •8489 views
Detailed explanation of the use of plate heat exchangers Plate heat exchangers are widely used, except in thermal It is used in ventilation and air conditioning systems and is also used in many other places. 1: Principle and classification of plate heat exchangers Plate heat exchangers are made by pressing thin metal plates into heat exchange plates with a certain corrugated shape, and then stacking them with plywoodRW Escorts, bolt issued on 04-3014:28 •4526 views
Application scope of plate heat exchanger Let’s find out the situation! Application scope of plate heat exchanger 1. Refrigeration: used as condenser and evaporator. 2. Heat ventilation and air conditioning: central heat exchangers for common boiler applications, central heat exchangers for high-rise buildings, etc. 3. Issued on 09-09 12:08 •2496 views
About the spiral plate Rwanda Sugar Daddy heat exchanger The spiral plate heat exchanger is a high-efficiency heat exchanger equipment, suitable for steam-steam, steam-liquid, liquid-liquid, and liquid-to-liquid heat transfer. It is suitable for chemical, petroleum, solvent, medicine, food, light industry, textile, metallurgy, steel rolling, coking and other industries. According to the structural form, it can be divided into non-detachable (type I) spiral plate type and detachable (type II, type III) spiral. Published on 04-23 10:48 •3348 views
Spiral plate heat exchanger failure How to solve the problem: Spiral plate heat exchanger package Rwandans Escort includes cylinder, head, pipe, tube sheet, baffle, and receiver , flanges and other components, these components can produce various forms of failure under different working conditions and conditions surrounding Rwandans Sugardaddy media The spiral plate heat exchanger failed. Therefore, measures must be taken to prevent the heat exchanger Rwandans Escort from failure or damage. Published on 04-25 10:34 • 786 views
Factors affecting the application efficiency of spiral plate heat exchangers Spiral plate heat exchangers are used in food, agriculture, medicine, petrochemicals, coking, resin coating, environmental protection treatment, etc. Categories have been widely used. So what problems are often encountered in the actual use of spiral plate heat exchangers? What other problems will affect the use of spiral plate heat exchangers? Posted on 04-26 10:36 •1442 views
What are the common faults of plate heat exchangers? There are many types of heat exchange equipment, such as: Spiral plate heat exchangers heat exchanger, plate heat exchanger, etc. However, from the cold point of view, the principles and methods of thermal fluid heat exchange can basically be divided into three types, namely: partition type, hybrid type and regenerative type heat exchanger. Type heat exchangerRW Escorts is used more. Spiral Published on 04-29 09:50 •2571 views
Features of Spiral Plate Heat Exchanger Spiral plate heat exchanger without dead angle is a high-efficiency heat exchanger equipment, suitable for steam-steam, steam-liquid, liquid-liquid, and liquid-to-liquid heat transfer. It is suitable for chemical, petroleum, solvent, medicine, food, light industry, textile, metallurgy, steel rolling, coking and other industries. This article mainly introduces the Rwandans Escort characteristics of spiral plate heat exchangers. Published on 06-02 10:09 • 902 views
Working principle of plate heat exchanger Installation and use methods of plate heat exchanger Plate heat exchanger is a common heat exchange equipment, mainly used for heat exchange processes heat conduction in. It consists of a series of flat plates, and there is heat conduction between these flat plates to complete the transfer of heat energy. This article will introduce in detail the working principle, installation and application methods of plate heat exchangers. 1. Plate heat exchanger's avatar Published on 02-14 17:10 •6492 views
What are the differences between plate heat exchangers and tubular heat exchangers? ? What are the differences between plate heat exchangers and tube heat exchangers? Plate heat exchangers and tube heat exchangers are two common heat exchange equipment used for heat energy transfer in industrial production. There are some differences between them in terms of structure, working principles, practical applications, etc. Next, we will introduce in detail 's avatar Published on 01-30 17:26 •24Rwanda Sugar28 views
Working principle of plate heat exchanger Installation and use of plate heat exchanger Plate heat exchanger is a Rwanda Sugar Commonly used heat exchange equipment, which transfers heat from hot fluid to cold fluid by flowing hot and cold fluids through both sides of the plate heat exchanger respectively, thereby achieving heat transfer and efficient use of energy. This article will introduce in detail the working principle, installation and application methods of plate heat exchangers. 1 's avatar Issued on 02-20 16:10 •2801 views


留言

發佈留言

發佈留言必須填寫的電子郵件地址不會公開。 必填欄位標示為 *