1. Device Later preparation: design

Design house graphene geothermal heating and heating construction drawings

According to the square number of the room space, design the corresponding heating area and power wattage and Spacing between geothermal units. As shown below

2. Installation data preparation

According to the design drawing, prepare the data required for the construction of the graphene geothermal heating device:

The information includes: graphene heating film, distribution box and parallel waterproof main line, reflective film, insulation board, intelligent thermostat, and air-start switch.

3. Installation construction: design distribution boxAnd circuits

Construction entry point:

When the decoration project arrives at the electrician’s site, determine the size of the electrical box, leakage protection and the number of north and south pole switch equipment. Determine the temperature control position of each area and place 2.5 square meters of wires.

3.1 The electrical box must have enough space to place: each circuit leakage protector in the exhibition floor tile area (2800W/piece)

3.2 Each circuit in the exhibition floor area Bipolar open. (2800W/piece)

3.3 Wiring shall be carried out according to the construction design standards: independent leakage protection and independent control, without passing through the original house’s total leakage protection.

3.4 The total power meets the geothermal system requirements.

4. Ground installation site requirements

Installation entry point: Before the painter finishes the construction and prepares the exhibition floor.

4.1 Ground drop requirements

4.2 The horizontal drop of floor tiles for overhead exhibitions should be 1~1.5cm

4.3 The horizontal drop of floors for overhead exhibitions should not exceed 0.2~0.4 cm

4.4 The ground is required to be clean, tidy and free of debris and garbage.

5. Overview of floor construction process

5.1 Exhibition of reflective film;

5.2 Exhibition of insulation board

p>

5.3 Place the temperature control probe wire

5.4 Exhibit the ecological graphene smart geothermal film;

5.5 Connect the wires;

5.6 Install the temperature control device, power-on detection.

6. Overview of floor tile construction process

6.1 Display of reflective film;

6.2 Display of floor tiles Insulation board;

6.3 Place the probe line;

6.4 Exhibit the ecological graphene geothermal film;

6.5 Exhibit the nano thermal conductor;

6.6 Connecting PVC wiring pipes

6.7 Power-on test;

6.8 Exhibiting PU film

6.9 Second test after the floor tiles are installed

7. Graphene geothermal actual construction process: display of reflective film and insulation board

7.1 Full display of reflective film on the original underlying ground

7.2 According to the wiring position in the drawing, the preview is not limited to two centimeters of slots

7.3 The two insulation boards at the end will not be installed until the power cord is laid out and placed in the reservation. Bit.

7.4 Insulation board RW Escorts should be cut neatly, with a gap less than 5mn.

7.5 Use Tape over cracks between insulation boards.

7.6 The surface of the insulation board is smooth.It is strictly prohibited to splice small pieces according to the measurement.

8. The actual construction process of graphene geothermal: Place the probe line (according to the drawing, place the temperature control probe in a slot)

8.1 The distance between the probe and the edge of the heating film More than 15cm inward;

8.2 The upper part of the probe position cannot be covered with furniture;

8.3 Stick the probe wire with tape to make way for the probe position;

8.4 The probe wire is threaded through the pipe Put the box on the wall.

9. Practical construction process of graphene geothermal: display nanotube thermal conductive film

Paste it with the merging of two heating films so that there is no cold gap in the geothermal , and stick it with adhesive tape.

10. Realistic construction process of graphene geothermal: installation of thermostat and debugging

10.1 Installation of thermostat;

10.2 Download the “Thermostat APP” on your mobile phone

10.3 Thermostat debugging settings;

11. Graphene geothermal device detection : On-site inspection

11.1 Use a thermometer to detect the surface temperature

11.2 Due to different ambient temperatures, the heating rate is different;

11.3 The surface temperature should rise quickly to higher than the ambient temperature;

11.4 If there is no temperature rise, please test the product and circuit;

12. Graphene geothermal device testing: secondary Detect floor tile leakage current detection

12.1 Leakage current detection;

12.2 Detection when power is on;

12.3 Adjust the clamp ammeter to the leakage current detection gear;

12.4 Measure the leakage current of each thermostat circuit;

12.5 The leakage current of each circuit should be less than 15MA;

12.6 If it is greater than 15MA, adjust leakage protection

13. Graphene geothermal device detection: secondary detection megger detection

Rwanda Sugar Daddy13.1 Test insulation resistance, a must-test item for floor tiles/PVC;

13.2 Test under power outage;

13.3 Megger One end of the floor heating plate leads out the terminal wire;

The other end of the 13.4 megohmmeter is partially immersed in the ground;

The reading of the 13.5 megohmmeter should be greater than 0.5MΩ, if it is less than 0.5MΩ, it means The floor heating plate or circuit may be damaged

13.6 Replace the terminal wire at the other end of the floor heating and test again.

14. Completion

Example of the aftermath diagram of the completion site


Problems and precautions that may be encountered in the use of optical modules Common problems and precautions in the use of optical modules: Compatibility Sexual problems, temperature problems, plug-in operation problems, and fault diagnosis problems. 2024-03-11 15:32:0784 overvoltage dimensionRwanda Sugar What are the precautions for installing an overvoltage protector? What are the precautions for installing an overvoltage protector? The environment around the site: When installing an overvoltage protector, the influence of the environment around the site needs to be considered. If the conditions around the site are severe, such as too low or too high temperature, too high humidity, etc., it may affect the performance and stability of the overvoltage protector. In this case, you need to choose the right 2024-03-11 11:22:10101 thermocouple Usage Methods Thermocouple Installation and Usage Precautions Thermocouple Usage Methods Thermocouple Installation and Usage Precautions Thermocouple is a common temperature measuring instrument, usually made of thermocouple wire composed of two different metals. When there is a temperature difference at the junction of two metals, an electromotive force will be generated, which can be calculated by measuring the electromotive force 2024-03-06 14:58:54295 New energy car charging pile installation and safety precautions New energy car charging pile installation and safety precautions Zhang Yingjiao Ankerui Electric Co., Ltd. Shanghai Jiading 201801 Abstract: The country promotes green environmental protection. New energy electric cars emerged as the times require, using clean energy to replace conventional energy without polluting the natural environment and reducing consumption. 2024-02-26 10:50:28287Graphene ElectricExploring a new chapter in future energy storage: High-performance 4.2V 5500F 2.6Ah graphene capacitor recommendation With the rapid development of technology, our demand for energy storage is also increasing. Among the many energy storage components, graphene capacitors are gradually emerging due to their unique advantages2024-02-21 20:28:36 The working principle of wireless bridge, the installation precautions of wireless bridge, the working principle of wireless bridge, the installation notes of wireless bridgeRwanda Sugar Daddy Note: A wireless bridge is a device used to expand the coverage of a wireless network. It can connect two or more networks through wireless electronic signals to achieve interconnection between different networks. Wireless bridges are usually composed of a transmitter and a receiver. The transmitter2024-02-03 16:27:29 299 Precautions for low-temperature use of the RX66N group. The electronic enthusiast website provides “Precautions for low-temperature use of the RX66N group.pdf” material for free download 2024-01-29 11:22:580 Precautions for low-temperature operation of the RX72N group. The electronic enthusiast website provides “Precautions for low-temperature operation of the RX72N group.pdf” material for free download 2024-01-29 11:21 :260 Precautions for low-temperature operation of the RX78M group The electronic enthusiast website provides “Precautions for low-temperature operation of the RX78M group.pdf 》Material download for free 2024-01-29 11:19:170 graphene powder (graphene Giving birth) Graphene powder is a new type of nanomaterial with a single-layer sheet structure composed of carbon atoms. Due to its excellent electrical conductivity, thermal conductivity and heat dissipation, all walks of life have placed high hopes on it. Graphene powder is suitable for energy storage and power batteries, new energy, thermal management, new building materials, health, solar energy, electronics2024-01-28 10:30:58 Electronic load parallel operation and precautions Electronic load parallel connection Operations and precautionsItem Electronic load is a device for testing and simulating circuit loads, which can simulate current and voltage under different load conditions. Parallel operation of electronic loads refers to connecting two or more electronic loads together to increase load capacity and flexibility. Through parallel operation 2024-01-22 13:42:56Usage and attention of 185 surge suppressor Matter? RW Escorts How to use and pay attention to the surge suppressor? | Shenzhen Bichuangda Electronics 2024-01-19 09:55:4195Speed ​​measuring motor: 6 common precautions. Speed ​​measuring motor: 6 common precautions! The tachometer motor is a device used to measure the movement speed of objects and is widely used in industrial production and scientific research. 6 common precautions for speed measuring motors to ensure safety and accuracy Rwandans Sugardaddy. 2024-01-11 10:53:36120Notes on the application of chip gold wire encapsulantRwandans EscortThe matters are What? What are the precautions for using chip gold wire encapsulant? Gold wire encapsulant is a high-performance, high-viscosity sealant that is widely used in electronics, electrical appliances, cars and other fields. It has excellent waterproof, moisture-proof, shock-proof and other properties, which can protect the internal parts of the product from the surrounding environment and improve the service life of the product 2024-01-05 11:29:38381Notes on Installation and Use of AWS Angle Sensors Installation and Use AWS Angle Sensor Considerations Installing and using AWS Angle Sensors is an important and complex task. Used to monitor and collect surrounding situation data, such as temperature, humidity, air pressure, etc., to help monitor the status of the equipment and predict possible problems during installation 2024-01-04 16:00:56162 Important Precautions for Optical Cable Installation Important Precautions for Optical Cable Installation Optical cable installation is one of the key steps in building an optical fiber network. Its correct installation is critical to the network. The quality and stability of the tool are crucial. The following will introduce you to the important precautions for optical cable installation. First, you must plan and design the optical cable before installing it. Precautions and abnormal noises when installing the 198 harmonic accelerator. Please strictly follow the following instructions when disassembling. Precautions for disassembly of the wave accelerator. 1. Precautions for the wave generator during assembly. The wave generator can be removed smoothly by rotating it. .Using wave generation without Euclidian coupling structure2023-12-26 08:36:57135DC power supply What are the precautions and application skills for the module? What are the precautions and application techniques for the DC power module? 2023-12-25 13:59:35175What is negative pressure gasFlow meter? What precautions should be taken when using a negative pressure gas flow meter? It is a very important tool, including medical equipment, petrochemical industry, surrounding situation monitoring, etc. When using a negative pressure gas flow meter, there are some precautions that need to be followed to ensure correct measurement and safe operation. The following are some key considerations: 1. Installation location: Choose an appropriate location to install the negative pressure gas flow meter to ensure accurate measurement 2023-12-19 09:38:36The working principle of the 356 pull pressure sensor introduces the installation methods and precautions of the pull pressure sensor. The working principle of the pull pressure sensor introduces the installation methods of the pull pressure sensor. Pull pressure A sensor is a sensor used to measure the force exerted on an object. It can convert the tension or pressure exerted by an object into electrical and electronic signal input for monitoring or controlling the system. Giving birth to children in industry, mechanical equipment 2023-12-18 15:35:11Notes on the application of 1424 Hall components Regarding its service life, there are some precautions that need to be kept in mind. This article will introduce in detail the precautions for the use of Hall elements. 1. Precautions for installation 1. The Hall element needs to be installed on the circuit board correctly, ensuring that the distance between it and surrounding components is appropriate to prevent electronic signal interference. 2. During the installation process, excessive bending or twisting should be avoided 2023-12-18 14:56:17 Things to note when installing 326 curved guide rails: You need to be aware of some installation precautions! 1. Before installing the curved guide rail, you should choose a dry and dust-free surrounding environment to avoid installation in a surrounding environment with water, oil stains or impurities to avoid damage to the guide rail. 2023-12-15 17:47:23 Precautions for the use of current transformers When it comes to the use of current transformers, there are some important precautions that we need to keep in mind. In this article, we will examine these considerations to provide you with detailed and comprehensive information. 2023-12-15 10:34:31429Distribution network traveling wave fault warning and Rwandans Escort positioning device play an increasingly important role in team installation work . This device can predict and locate faults in advance by monitoring traveling wave electronic signals in the distribution network, effectively improving the stability and reliability of the power system in order to ensure the correct installation and application of traveling wave fault warning and positioning devices in the distribution network. , this article will introduce in detail the precautions for team installation 2. 2023-12-14 16:41:00 What are the precautions for the purchase, installation and use of the 1763 power filter? What are the precautions for the purchase, installation and use of the power filter? Power filter Viaip power filter is mainly installed in the main power output circuit. , located between the equipment and the power grid. Therefore, on the one hand, it can prevent the electromagnetic interference of the equipment from being transmitted to the power grid through the power line, exceeding the standard value; on the other hand, the equipment is strengthened to resist the interference of the electromagnetic interference transmitted from the power grid to the equipment. Make the equipment run more stable and also meet the standard requirements of anti-interference 2023-12-05 10:27:55316Precautions for installation and use of distribution boxes Distribution boxes are essential in modern homes and businesses The installation and use of power distribution equipment are crucial to the safety and stability of the power system. However, during the installation and use of distribution boxes, electrical safety accidents may occur due to lack of safety awareness or unclear relevant regulations. 2023-12-01 10:51:21425pRwanda Sugar DaddyCb board circuit corrosion and cleaning precautions PCB board circuit corrosion and cleaning precautions Matter2023-11-24 17:21:17What are the installation operations and precautions of the 386 box-type furnace? The box-type low-temperature sintering furnace integrates the control system and the furnace. The furnace lining is made of vacuum-formed high-purity alumina polylight material, and the heating element is silicon Molybdenum rods or silicon carbide rods are suitable for sintering, melting, analyzing and other operations of metals, non-metals and other chemical materials. Precautions for equipment use include checking the power supply and connections. com/”>Rwandans Escort Floor maintenance, air switch, etc. should comply with the heating speed requirements during use, and regularly check the connection between the electrical connection part and the heating element. 2023-11-24 16:33:21225PCBdesign considerations for VGA OUT PCBdesign considerations for VGA OUT2023-11-23 09:04:58271PADS VX2.7 Precautions for downloading, installing and 3D model import://mentor.mr-wu.cn/The installation method can be completed according to the instructions in the installation package. Precautions for cracking: 1. Use the latest version of Mantou Crack 2. The anti-virus software must be turned off, otherwise it will not work after cracking! 2: 3D model import 1. From the 3D model website 2023-11-22 17:54:57 Potentiometer wiring method, installation method and usage precautions The wiring method, installation method and application selection precautions of the potentiometer are an electronic component that can adjust the resistance. It is often used to change the resistance in the circuit. Its wiring method, installation method and application selection precautions are very important to the user. Important. The following will introduce the potentiometer in detail 2023-11-22 17:15:004514 vibrating wire penetration Installation method and precautions of vibrating wire piezometer. Installation method and precautions of vibrating wire piezometer. The vibrating wire piezometer is a commonly used instrument for measuring soil water level. It can be used to monitor groundwater level, soil moisture content, and rock layer infiltration. Coefficient and other parameters. The principle is to measure the pressure change in the medium based on the change of the resonant frequency of the vibrating wire 2023-11-2013:27:38267How to install solar off-grid inverter power supply? Things that require special attention during installation How to install solar off-grid inverter power supply? Things that require special attention during installation: Solar off-grid inverter power supply is a device that converts solar energy into transportation electricity. It is suitable for use in some remote areas where traditional power grids cannot be connected. The installation process requires special attention to the following matters. 1.2023-11-16 11:22:49409 Methods and precautions for installing general strain gauges Installing general strain gauges Methods and precautions Overview Strain gauges are widely used in water conservancy projects and concrete structures to measure linear deformation (strain) and stress at embedded points, and can also measure temperature. They can be divided into two types: surface-mounted and embedded. Device Overview Strain Gauge Method 2023-11-13 13:31:51269What are the precautions for sensor installation? What are the precautions for sensor installation? Smart sensor steel bar gauge strain gauge data collection. When installing the sensor, you need to Pay attention to the following points: Ensure that the sensor can accurately sense the target object or surrounding conditions and is not affected by other internal interference. The installation position of the sensor should be as close as possible to the target 2023-11-08 09:19:38406 Ziguang Tongchuang DDR3_IP_example simulation Operations and Precautions DDR3_IP_example Simulation Operations and Precautions#UNISOC PDS Software Operation Guide#Pangu Series Development Board Software Application Guide~~2023-11-02 17:47:19 When do you feed the dog? How to feed a dog? What are the precautions for feeding a dog? When to feed a dog? How to feed the dog? Feed the dogThings to note? 2023-10-27 07:30:49 What should you pay attention to when using composite robots? Composite robots are widely used in various Rwandans Sugardaddy fields and have the advantages of high efficiency, precision, and maneuverability. When using it, you need to pay attention to the installation requirements, usage precautions and maintenance precautions to ensure safe and effective use. 2023-10-26 17:42:15How to use the 425 power filter correctly? What should you pay attention to when installing a power filter? How to use power filter correctly? What should you pay attention to when installing a power filter? The power filter is a common power device, mainly used to reduce the noise, spike, and ripple of the power supply, thereby ensuring the stability and reliability of the power supply. It is usually installed on many 2023-10-25 15:48:36902FAQ0133 Peripheral event abort response process and Notes: Peripheral event interruption response process and notes introduce a way to ensure that callback tasks can be responded to correctly 2023- 10-23 07:47:29 Notes on matters needing attention when using erase SPIM Notes on matters needing attention when using erase SPIM When the operation code for erasing SPIM is placed in the non-zero waiting area (NZW), it may cause program execution exceptions and hardfault. Wait for the fault. 2023-10-23 06:55:56 Precautions when installing a vibrating wire collector at high temperatures. Precautions when installing a vibrating wire collector at high temperatures. The vibrating wire collector is a device used to measure and monitor the vibration conditions of structures. It is usually used in bridges. , monitoring and evaluation of large buildings, wind turbines, ships and other facilities. In some cold areas, the environment around the use of facilities will face high temperature challenges, so 2023-10-16 11:02:081678-bit MCU EEPROM Application Precautions Zhongying 8-bit MCU EEPROM Application Precautions 2023-09-27 15:34:13433 Precautions when installing the leakage protector: voltage, rated current, breaking time of rated leakage action current Whether the parameters are consistent with the selected ones. 2. Connect the leakage protector to the power supply under no-load condition, and then press the check button to check whether the action is correct. 2. Precautions during installation 1. Requirements for power supply system 1) Voltage action leakage protector must be used 2023-09-22 14:40:591103SC5 PCIe board installation and application considerations Distribute to friends 1. Precautions related to installation SC5 Quick Installation Guide 1. Install SC5 into the PCIe slot when the host is turned off. It needs to be inserted into place. SC5 is powered directly from the PCIe interface and does not require an external ATX 2×3 power supply. Note that it is best to unplug the server 2023-09-20 06:11:27 Keywords for precautions in the installation and wiring of the fire residual pressure controller: residual pressure controller, installation, wiring, precautions The residual pressure controller is a residual pressure monitor An important part of the system; the residual pressure controller can match a variety of electric actuators, including 24v, 220V, 7 wires, 6 wires, 5 wires, 4 wires, analog values ​​and switching values; Residual pressure controller 2023-09 -11 16:53:40534Installation Precautions for Radar Level Gauge Radar level gauge is an instrument commonly used in industrial process control. It measures liquids by sending and receiving radar electronic signals. height. When installing a radar level meter, we must follow aSome precautions should be taken to ensure its accuracy and reliability. This article will introduce the installation precautions of radar level gauge. First 2023-09-05 16:01:21What should you pay attention to when purchasing a 421 electric spindle? What should you pay attention to when purchasing an electric spindle? |Shenzhen Hengxinglong Mechanical and Electrical 2023-09-05 10:35:27479 Vertiv Communication Power Supply NetSure731A61-S4 Safe Precautions: Personnel who install and operate the company’s products must undergo strict training and master the correct operation methods of the system and various safety precautions before operating the equipment. When performing various uses of our company’s products and equipment, you must abide by the relevant industry regulations 2023-09-01 16:27:44709Single Hall\ Floor heating fan\ BLDC uses a common chip (MDRH40) single Hall \Ground heating fan\ BLDC uses special chip (MDRH40) [url=https://www.bilibili.com/video/BV1oh4y1T7Md/][/url2023-08-31 17:14:42What should we pay attention to when installing safety gratings? What should we pay attention to when installing safety grating? 1. Determine the appropriate safety grating type based on the equipment type and protection requirements to effectively protect personnel safety. 2. Based on the requirements of the equipment, the actual operation methods of employees and the model of the light curtain, determine the appropriate installation location to avoid improper installation location 2023-08-28 09:27Rwanda Sugar:11240What you need to know when installing the encoder sensor3 major precautions: In the assembly of mechanical equipment, there are 3 major precautions that need to be understood when installing encoder sensors. 1. Mechanical precautions 1. The encoder sensor and the user input shaft cannot be connected rigidly. An elastic and soft connection should be used to avoid the encoder shaft system caused by the movement, beating, shaking, eccentricity, etc. of the user shaft 2023-08- 27 08:08:34687Precautions for the operation of the linear module Precautions for the operation of the linear module 2023-08-21 17:36:22854PCB laser marking Where should the machine not be used and what precautions should be taken when using it? Where should the PCB laser marking machine not be used and what precautions should be taken when using it. With the rapid development of laser technology, laser marking machines have also developed rapidly. Laser equipment marking technology is highly sought after in all walks of life. As market demand continues to expand, market competition has also intensified. What should be paid attention to when using electric spindles in various industries 2023-08-18 10:00:39? What precautions should be taken when using electric spindle? |Shenzhen Hengxinglong Mechanical and Electrical 2023-08-16 11:16:11543Safety Light Curtain Installation Precautions Safety Light Curtain Installation Precautions Safety light curtains are widely used in automation, machining and other work fields , and continue to bring efficiency and safety to the enterprise. So what should you pay attention to when installing the safety grating? 1. It is necessary to determine the safety of the appropriate model based on the type of equipment and maintenance requirements 2023-08-01 15:32:23309 Summary of things to note in PCB power supply design Today is mainly about: 7 things to note in PCB power supply design. 2023-07-31 15:04:48936Required when selecting SMD beads Parameters to consider, SMD magnetic bead selection considerations SMD magnetic beads, also known as SMD inductor beads or surface mount inductor beads, are important components in electronic circuits. They are used to filter or control electromagnetic interference in various applications. Unnecessary electromagnetic interference (EMI). This article will introduce the parameters and considerations when selecting chip beads 2023-07-27 09:55:321418 Steps and precautions for installing a permanent magnet synchronous motor. The permanent magnet synchronous motor is a high-efficiency, low-noise motor with a wide range of applications, such as electric vehicles, wind power generation, Industrial automation, etc. For the installation of permanent magnet synchronous motors, certain steps need to be followed. Below we will introduce in detail the steps and precautions on how to install permanent magnet synchronous motors. 2023-07-21 17:18:04What are the operating procedures and operating precautions of the 776 welding robot? The welding robot is a kind of welding program that is preset to In the robot control system, the robot automatically completes the welding operation. It not only improves the efficiency of childbirth and reduces the cost of childbirth, but also effectively ensures the quality and stability of the welding tools. Robot store Wuxi Jin Hongying will introduce in detail the operating procedures and precautions of the welding robot 2023-07-18 16:29:47The handling precautions of the 919 robot palletizer may cause injury to workers. The handling precautions of the palletizing robot: 1. When using a crane or forklift to move the palletizer Rwanda Sugar robot, it is definitely not possible to manually support the palletizing robot control box. 2. Do not lie on or stand on the palletizing robot during transfer.Under the lifted palletizing robot. 3. Before stopping the equipment, please disconnect the air controller power supply. 4. Install the palletizing machine 2023-07-18 11:02:40163Install safety grating What should we pay attention to? When installing a safety grating, you need to pay attention to the following points: 1. Determine the appropriate type of safety grating based on the type of equipment and protection requirements to effectively protect personnel safety. 2. Based on the requirements of the equipment, the actual operation methods of employees and the model of the light curtain, determine the appropriate installation location to avoid errors due to installation location 2023-07-17 15:42:01232What should you pay attention to when using fluorescent lamps When using fluorescent lamps, you must pay attention to the correct wiring method. Whether it is installed or used, it must be in accordance with the standards. You can take a look at the following 8 precautions. 2023-07-15 15:25:23What are the technical requirements for 571 lighting circuits and matters needing attention when installing lighting equipment There is knowledge about lighting circuits. When wiring lighting circuits, they must be operated according to certain technical requirements. There are 11 major items. There are 8 major items to pay attention to when installing lighting equipment. Friends in need. For reference. 2023-07-15 15:00:502183 Safety Grating Selection Precautions Safety Grating Selection Precautions 2023-07 -14 10:24:38507Precautions for the first use of the modulation driver. When using the modulation driver for the first time, there are several precautions to consider. 2023-07-10 11:47:02409 Application Precautions Application Precautions 2023-07-07 19:04:510 Safety light curtain selection methods and precautions Safety light curtain selection methods and precautions 2023-07-06 13:59:01423Safety light curtain selection methods and precautions Safety light curtain selection methods and matters needing attention2023-06-28 14:35:09416128 Precautions for Instrument Installation and Daily Maintenance Operations Before instrument installation, the process pipeline should be purged to avoid retention in the pipeline. The ferromagnetic substances attached to the instrument will affect the performance of the instrument and may even damage the instrument. If it is unavoidable, a magnetic filter should be installed at the inlet of the instrument to prevent damage to the instrument. -06-27 16:33:23469 should pay attention to these details when installing remote magnetic flap level meter: To make the remote transmitter work better, when installing it together with the magnetic flap level gauge, in addition to following the normal installation method of the magnetic flap level gauge, you should also pay attention to the following matters 2023-06-21 16. :54:09331 What are the precautions for GPIO application? GPIO application precautions 2023-06-21 06:03:22 Five important things to note when installing an OLED splicing screen. The OLED splicing screen is a high-end display screen, which is spliced ​​by multiple OLED screens and can achieve high definition. , high brightness, high contrast display effect. When installing OLED splicing screens, you need to pay attention to the following points: 1. Rwandans Escort Determine the installation location: ORW EscortsLED splicing screens are usually used in business2023-06-16 09:58:31362Dinghua Radar Knowledge Class: Guided Wave Radar Precautions for the installation of the level meter 1. Installation Guide: Do not contact the cable or rod with external obstacles within the entire range. Therefore, when installing, try to avoid facilities inside the tank, such as: ladders, limit switches, Heating equipment, brackets, etc. In addition, it should be noted that the cable or rod must not intersect with the feeding material flow. 2. When installing the instrument, you need to pay attention to: the highest 2023-06-RW Escorts14 10:34:04335 Precautions for on-site installation and maintenance of PLC. When installing and maintaining PLC, you should pay attention to the following issuesRwanda Sugar: 1. Installation of PLC When installing a PLC, avoid the following situations: (1) The ambient temperature exceeds the range of 0 ~ 50°C; (2) The relative humidity exceeds 85% or there may be dew condensation (caused by temperature gradients or other reasons); ( 3) Direct sunlight; (4) Corrosive and flammable gas 2023-06-12 09:46:12359Linear Magnetic Grating Encoder丨Key precautions for magnetic linear displacement sensor installation The installation process is the key to ensuring its performance. This article will introduce the key precautions for magnetic scale installation to ensure measurement accuracy and system reliability. Determine the installation position and direction: When installing the magnetic scale | linear magnetic encoder | magnetic linear position 2023-06-09 15:01:42647What are the precautions for the actual operation of the BGA rework station? ? In the actual operation of the BGA rework station, it should be operated with caution, and the precautions are very important. The following is a detailed introduction to the precautions in the actual operation of the BGA rework station. 2023-06-07 13:47:2142489BSD-012BS-A Sensor Installation Precautions The accuracy of the electronic platform scale is It is determined based on the 89BSD-012BS-A sensor on the electronic scale. For this reason, we need to pay attention to some things when installing the sensor in order to better encapsulate the accuracy of the 89BSD-012BS-A sensor. So let us take a look at the things that should be paid attention to when installing the 89BSD-012BS-A sensor. 2023-06-07 11:25:45295What are the precautions for using BGA rework equipment? -Zhicheng Jingzhan Before operating the equipment, users should read the equipment instruction manual carefully and understand the operating procedures, safety operating regulations and precautions.Item; 2. When using, you should wear specially designed safety protective equipment to avoid unsafe situations caused by dust, heat, etc.; 3. The area where the equipment is used should be kept clean, and it is strictly prohibited to use it near low temperatures, high pressures, and flammable and explosive areas. 2023-06-06 14:40:07How to install 427PLC? As we all know, PLC is not just a Common sense is more of a skill. If you only learn to understand the practice but don’t know how to practice it, no matter how fierce you are, it will be useless. For example, do you know how to install PLC? How to connect PLC? What are the precautions? Let’s go together 2023-05-23 15:43:49827 tensile testing machine installation instructions, installation tensile test What are the steps for the machine? The installation manual of the tensile testing machine refers to a manual that explains in detail the installation process of the tensile testing machine. The manual includes preparatory work before installation, matters needing attention during the installation process, acceptance criteria after installation, etc. Correct installation can ensure the normal operation of the tensile testing machine, thereby ensuring the accuracy of the test results. 2023-05-23 14:37:46548QB-780731 (Control code: A, B, C) Operation Precautions QB-780731 (Control Code: A, B, C) Operation Precautions 2023- 05-04 18:59:100QB-78K0KX2 (control code: B, C, D, E, F ) Operation Precautions QB-78K0KX2 (Control Code: B, C, D, E, F) Operation Precautions 2023-04-28 19:38:530PG-FP4 (control code: B, C, E, F, G, H) operation precautions PG-FP4 (control code: B, C, E, F, G, H) operation precautions 2023-04-27 19: 12:030 QB-MINI2 Operation Precautions QB-MINI2 Operation Precautions 2023-04-27 18:58: 430QB-78K0RKX3 (control code: E, F, G, H, J, K, L, M) Operation precautions QB-78K0RKX3 (control code: E, F, G, H, J, K, L, M) Operation precautions 2023-04-26 20:38:160QB-78K0SKX1 (Control code: A, B, C) Operation Precautions QB-78K0SKX1 (Control Code: A, B, C) Operation Precautions 2023-04 -26 20:27:470QB-78K0LX3 (control code: A, B, C, D) operation precautions Event QB-78K0LX3 (control code: A, B, C, D) operation precautions 2023-04-26 20:17:550SMT patch processing process and precautions One-stop PCBA smart manufacturing store will talk to everyone about SMT patch processing and production tomorrowRwandans EscortWhat does the process include? Matters needing attention in SMT chip processing. Next, I will introduce to you the processes and precautions in the SMT chip processing process. It has to be said that SMT should be the automation in the modern electronic assembly industry 2023-04-21 10:08:39 1045 electrical quality transmitter installation precautions Installation location: The electrical quality transmitter should be installed on the load side of the power system to avoid high voltage interference. At the same time, it is necessary to includeThe dustproof, waterproof and other functions of the tube transmitter prevent the internal and surrounding conditions from affecting the equipment. 2023-04-16 11:44:34367 What are the operating precautions when operating a universal testing machine? Inspection, installation, and calibration of the correct use of the universal testing machine and precautions, proper maintenance and troubleshooting of common errors can provide guarantee for the accuracy of the test results and the quality of the tool, ensuring the stability and reliability of the childbirth process. , improve the efficiency of childbirth and the quality of tools. 2023-04-14 11:33:26925What should we pay attention to when installing underground lights? What should we pay attention to when installing underground lights? RW EscortsUnderground lights are also called dark lights. LED underground light LED is a light source driven by LED constant current. It is a Rwandans Sugardaddy lighting and decorative light embedded in the air. Underground lights illuminate the ground and ground vegetation, beautifying the landscape and ensuring the safety of pedestrians. Then everyone understands the installation requirements of underground lights. Pay attention to 2023-04-14 11:32:13965 splicing screen installation Precautions for wiring: First assemble the splicing screen according to the instructions, and then use screws to install its fixing bracket on the splicing screen. The movement must be fixed on the fixed movement frame and installed at the selected installation location. fixed. 2023-04-14 10:40:38793 Precautions for spread spectrum IC layout Precautions for spread spectrum IC layout Matter 2023-04-14 10:12RW Escorts:054 Precautions for the use of wireless switching modules. Siwei Wireless today will introduce some precautions for the use of switching modules to prevent users from improper operation and causing damage to the wireless switching modules. Rework situation 2023-04-11 15:45:29583Precautions for photovoltaic power station installation In short, the installation of photovoltaic power stations involves site selection, structural design, component selection, grid connection, safety inspection and daily Maintenance and many other aspects. During the installation process, relevant regulations should be strictly followed to ensure safety and reliability and improve power generation efficiency. 2023-04-11 14:58:19What are the operating procedures and operating precautions of the 2703 welding robot? What are the operating procedures and operating precautions of a welding robot? The operating procedures of a welding robot: It is necessary to set up the welding robot, install the workpiece and clamp it, start it, start the preheating function, execute and check the quality of the welding tool. . Pay attention to the safety of operators 2023-03-29 08:59:011712Melt pressure sensor (transmitter) installation precautions and electrical connection and debugging when installing the sensor (transmitter) ) Be careful before proceeding. The following introduces some precautions for the installation and use of low-temperature melt pressure sensors (transmitters), and correct connection and debugging to ensure trouble-free operation. 2023-03-28 17:46:343800